Model |
HS-6763A( Quantity Method) |
|
Size |
DN15-DN25 |
|
Straight tube |
≥10D |
|
Water Meter Type |
Mechanical water meter, ultrasonic water meter, electromagnetic water meter, remote water meter |
|
Flow range |
(0.01~8)m3/h |
|
Position |
6 Positions |
|
Pressure |
0.3~0.6Mpa |
|
Test Method |
start-stop method,commutation method,flow time method |
|
Reference Gauge |
120Kg,E=1/6000 |
|
Display value |
5g,10g,20g |
|
Max.error |
>±0.1%( above min. weighing ) |
|
uncertainty |
Ur=(0.05%~0.2%),k=2 |
|
Stability |
>0.2% |
|
Pulse collection |
Pulse:f=(0~10)kHz;?Visual recognition, laser recognition. Communication:M-BUS、485、near-infrared |
|
Signal trasmission |
Cell phone app wireless transmission, visual identification, laser identification sensor (mechanical water meter) Far infrared,485 communication, M-bus communication (remote water meter) |
|
Clock frequency |
(10~100)kHz(Can setup) |
|
Stability of clock frequency |
>5×10-8 |
|
Temperature |
(20±5)℃(Option) |
|
Dimension |
5m×3m×3.5m(L×W×H) |
|
Model |
HS-6763B(?Volumetric method ) |
|
Size |
DN15-DN25 |
|
Straight tube |
≥10D |
|
Water Meter Type |
Mechanical water meter, ultrasonic water meter, electromagnetic water meter, remote water meter |
|
Flow range |
(0.01~8)m3/h |
|
Position |
6 Positions |
|
Pressure |
0.3~0.6Mpa |
|
Test Method |
start-stop method,commutation method,flow time method |
|
Reference Gauge (?String gourd method ) |
10L/20L 50L/100L |
|
uncertainty |
Ur=(0.05%~0.2%),k=2 |
|
Stability |
>0.2% |
|
Pulse collection |
Pulse:f=(0~10)kHz; Visual recognition, laser recognition. Communication:M-BUS、485、near-infrared |
|
Signal trasmission |
Cell phone app wireless transmission, visual identification, laser identification sensor (mechanical water meter) Far infrared,485 communication, M-bus communication (remote water meter) |
|
Clock frequency |
(10~100)kHz( Can setup ) |
|
Stability of clock frequency |
> 5×10-8 |
|
Temperature |
(20±5)℃( Option ) |
|